9- 22
Service Guide
LWE180, LWE200, LPE200, LPE240
© BT Europe AB
Electrical System – 5000 LWE 180/200 LPE 200
Error codes
T-code
Valid from serial number
Date
Order number
660, 661, 662, 497
723984-
2005-05-11
225553-040
Code
C90 (Option)
Description
Extra I/0 (0) CAN communication error
Possible error
cause
Data from extra I/0 box /(0) not being received by
[A2]/ Check the CAN-bus cable and the
connections. [A2] Restart the truck
.
Code
C91 (Option)
Description
Extra I/0 (1) CAN communication error
Possible error
cause
Data from extra I/0 box /(1) not being received by
[A2]/ Check the CAN-bus cable and the
connections. [A2] Restart the truck
.
Code
C92 (Option)
Description
Configuration error Extra I/0 (0)
Possible error
cause
Incorrect setting of options in the extra I/0 box (0)
Check the outputs’ allocation on the I/0 expansion
box (0)
Code
C93 (Option)
Description
Configuration error Extra I/0 (1)
Possible error
cause
Incorrect setting of options in the extra I/0 box (1)
Check the outputs’ allocation on the I/0 expansion
box (1)