10- 18
Service Guide
LWE180, LWE200, LPE200, LPE240
© BT Europe AB
Electrical systems – 5000 LPE 240
Error codes
T-code
Valid from serial number
Date
Order number
660, 661, 662, 497
723984-
2005-05-11
225553-040
Code
C90 (Option)
Description
Extra I/0 (0) CAN communication error
Possible error
cause
Data from extra I/0 box /(0) not being received by
[A2]/ Check the CAN-bus cable and the
connections. [A2] Restart the truck
.
Code
C91 (Option)
Description
Extra I/0 (1) CAN communication error
Possible error
cause
Data from extra I/0 box /(1) not being received by
[A2]/ Check the CAN-bus cable and the
connections. [A2] Restart the truck
.
Code
C92 (Option)
Description
Configuration error Extra I/0 (0)
Possible error
cause
Incorrect setting of options in the extra I/0 box (0)
Check the outputs’ allocation on the I/0 expansion
box (0)
Code
C93 (Option)
Description
Configuration error Extra I/0 (1)
Possible error
cause
Incorrect setting of options in the extra I/0 box (1)
Check the outputs’ allocation on the I/0 expansion
box (1)
Code
E101
Description
Travel regulator does not correspond with the type
of truck
Possible error
cause
Incorrect travel regulator or electronic card has
been installed. The truck has a built-in control
function that checks to ensure the wrong combina-
tion of travel regulator and electronic card has not
been installed.
Action
Check travel regulator and electronic card.