Electrical systems – 5000 LPE 240
Parameters
Order number
Date
Valid from serial number
T-code
225553-040
2005-05-11
723984-
660, 661, 662, 497
© BT Europe AB
Service Guide
LWE180, LWE200, LPE200, LPE240
10- 33
The parameter symbol is lit (i.e. stops flashing).
•
Select independent variable #1 by activating the speed control L1.
Independent variable value #1 is displayed after 1 second.
•
Press the horn button S18.
The parameter symbol flashes.
•
Enter the independent variable value #1 by repeatedly operating the
speed control L1 in either direction. See the list of optional functions
in Table 7:
•
Press the S18 horn button once to confirm the new setting.
The parameter symbol is lit (i.e. stops flashing).
Adjust independent variables #2, #3 and #4 in the same way as above.
•
Switch off the truck by pressing
on the keypad.
The optional function is now activated.
•
Check that the optional function works correctly before the truck is
put back in operation.
Table 7: List of configurable optional functions
Independent
variable #1
Independent
variable #2
Independent
variable #3
Independent
variable #4
Independent variable #0 = 1: The option button controls the spider output
0:Spider 0
1:Spider 1
0:Digital output 1
1:Digital output 2
2: :Digital output 3
3: :Digital output 4
1-6:option button 1-6
Type of function:
0:instantaneous
1:butterfly switch
Independent variable #0 = 2:Reduced running speed controlled by the spider’s digital input
0:Spider 0
1:Spider 1
0-7:Digital input 1-8
0-12:reduced speed
40-100%
(i.e. 40+5*arg3 e.g.
4: 40+5*4=60%)
0:high-speed range
1:low-speed range
2: both ranges
Independent variable #0 = 3:Activate the spider output for specific movements
0:Spider 0
1:Spider 1
0:Digital output 1
1:Digital output 2
2: :Digital output 3
3: :Digital output 4
Select movements.
See Table 8:
Initial position:
0: shines constantly
1: flashes 1 Hz
2: flashes 2 Hz