2-38
Confidential
Print Unable 08
Turn the power off and
then back on again.
An error occurred in the internal
temperature sensor.
Print Unable 09
Turn the power off and
then back on again.
Detected irregular power supply
for more than 100 times.
Print Unable 0A
Turn the power off and
then back on again.
Main PCB detected the main fan
failure.
Print Unable 0B
Turn the power off and
then back on again.
An error occurred in the high-
voltage power supply PCB ASSY
during the operation.
An error occurred in the high-
voltage power supply PCB ASSY
when the machine was in the
ready state.
Print Unable 17
Turn the power off and
then back on again.
Detected a TT fan failure.
Print Unable 18
Turn the power off and
then back on again.
A communication error occurred
between the main PCB and T2LT
control PCB.
A communication error occurred
between the main PCB and T3LT
control PCB.
A communication error occurred
between the main PCB and T4LT
control PCB.
A communication error occurred
between the main PCB and TT
control PCB.
Print Unable 19
Turn the power off and
then back on again.
Detected a TT motor failure.
Print Unable 1A
Turn the power off and
then back on again.
A communication error occurred
between the main PCB and MX
control PCB.
Print Unable 1B
Turn the power off and
then back on again.
Detected an MX motor failure.
Print Unable 38
Turn the power off and
then back on again.
A temperature error occurred in
the external temperature/humidity
sensor.
Print Unable 8B
Turn the power off and
then back on again.
Detected that the TT was not
turned ON.
Print Unable C1
Turn the power off and
then back on again.
Failed to save data to a USB flash
memory.
Print Unable E0
Turn the power off and
then back on again.
An error occurred at the ROM
check sum in the firmware.
Error message
Description
Error
codes
Refer
to:
First line