3-61
Confidential
9.10.8 Panel PCB ASSY
(1) Release the panel harness ASSY from the securing fixtures. Release the three hooks,
and remove the panel PCB ASSY. Release the lock, and remove the LCD FPC from the
panel PCB ASSY.
(2) Release the two hooks, and remove the LCD holder from the top cover printed ASSY.
(3) Remove the back light film and LCD from the top cover printed ASSY.
(4) Remove the LCD sheet from the top cover printed ASSY.
Fig. 3-48
Harness routing: Refer to
“5. Bottom side of the top cover ASSY (Non touch panel models)”
.
Panel PCB ASSY
LCD holder
Back light film
LCD
LCD sheet
Top cover printed ASSY
LCD FPC
Hooks
Hooks
Lock
Panel harness ASSY