3-97
Confidential
(2) Remove the HV insulation sheet.
(3) Release the HVPS flat cable from the securing fixtures.
(4) Remove the two taptite bind B M4x12 screws. Release the two hooks, and remove the
high-voltage power supply PCB ASSY and feed ground spring.
Fig. 3-86
Harness routing: Refer to
“8. Bottom side of the machine (High-voltage power supply PCB ASSY)”
.
Feed ground spring
Taptite bind B M4x12
Hooks
HV insulation sheet
High-voltage power
supply PCB ASSY
Taptite bind B M4x12
HVPS flat cable