7-11
Confidential
■
Non touch panel models
(15) Disconnect the panel harness ASSY from the main PCB ASSY, and release it from the
securing fixtures.
(16) Remove the four taptite bind B M4x12 screws.
(17) Release the hook A first, and then release the hook B. Remove the top cover ASSY.
Fig. 7-16
Harness routing: Refer to
“2. Left side of the machine (Non touch panel models)”
.
Top cover ASSY
Hooks B
Taptite bind
B M4x12
(black)
Hooks B
Taptite bind B M4x12
Main PCB ASSY
Panel harness ASSY
Hooks A