![Brother HL-5580D Service Manual Download Page 108](http://html.mh-extra.com/html/brother/hl-5580d/hl-5580d_service-manual_53668108.webp)
2-82
Confidential
Error code C800
The memory size allotted for Secure Print was exceeded when saving Secure Print data.
Error code D800
An error occurred while initializing the touch panel.
Error code E000
An error occurred in the ROM check sum.
Error code E100
Program error
<User Check>
• Print the print data stored in the memory.
• Divide the print data and print them separately.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Panel firmware version and
main firmware version do not
match
Install the latest main firmware.
2
Connection failure of the panel
PCB flat cable
Reconnect the panel PCB flat cable.
3
LCD relay PCB failure
Replace the LCD panel ASSY.
4
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Malfunction of the main
firmware
Install the latest main firmware.
2
Main PCB failure
Replace the main PCB ASSY.