![Brother DCP-110C Service Manual Download Page 416](http://html.mh-extra.com/html/brother/dcp-110c/dcp-110c_service-manual_53169416.webp)
App.
4-41
Confidential
WSW38
(V.34 transmission settings)
Selector
No.
Function
Setting and Specifications
1
2
Setting of the equalizer
No. 1 2
0 X
:
Automatic
1 0 : Fixed to 4 points
1 1 : Fixed to 16 points
3
Sending level of guard tone at
phase 2
0: Normal - 7 db
1: Normal
4
Stepping down the transmission
speed at fallback each
0: 2400 bps
1: 4800 bps
5
6
Automatic control of modem's
EQM gain for proper transmission
speed choice
No. 5 6
0 0 : For higher transmission speed
than the current setting
0 1 : No change from the current
setting
1 0 : For lower transmission speed
than
the
current
setting
1 1 : For further lower transmission
than the setting made by 1, 0
7
Redialing when a communications
error occurs
0:
ON
1:
OFF
8
Detection of CED for stopping
CNG
0:
ON
1:
OFF
NOTE:
WSW38 takes effect only when the V.34 mode is permitted (WSW19, selector 7) in models
supporting V.34 mode.
Selectors 1 and 2: Setting of the equalizer
These selectors set the equalizer's training level to be applied if the machine fails to send training
due to weak line connection. If these selectors are set to "0, X," the modem will automatically set
the appropriate training level.
Selector 3: Sending level of guard tone at phase 2
This selector sets the sending level of guard tone for 1800 Hz to be sent at Phase 2 in the V. 34
mode.
Selector 4: Stepping down the transmission speed at fallback each
This selector determines how much the modem steps down the transmission speed at fallback when
called by the remote station. If this selector is set to "1," the modem may step down the
transmission speed from 33600 bps to 28800 bps by one-time fallback.
Selectors 5 and 6: Automatic control of modem's EQM gain for proper transmission speed choice
These selectors determine how the modem controls the EQM (Eye Quality Monitor) gain for
proper choice of the transmission speed, which applies if the modem selects higher transmission
speed than the possible speed so that it always repeats falling back.
Selector 8: Detection of CED for stopping CNG
If this selector is set to "0," the detection time of CED specified by WSW43, selectors 4 and 5 will
apply.
Summary of Contents for DCP-110C
Page 10: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 14: ...1 3 Confidential 1 2 CONTROL PANEL MFC620CN FAX2440C ...
Page 17: ...1 6 Confidential MFC210C ...
Page 21: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 87: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 131: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 136: ...Confidential CHAPTER 55 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 212: ...5 74 Confidential Routing C Backup battery harness and ink supply tubes MFC620CN and FAX2440C ...
Page 214: ...5 76 Confidential Viewed from the left ...
Page 220: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 240: ...6 18 Confidential Vertical Alignment Check Patterns ...
Page 243: ...6 21 Confidential Margin Check Pattern ...
Page 253: ...Confidential CHAPTER 7 CLEANING ...
Page 256: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 267: ...8 9 Confidential Scanning Compensation Data List a b c d e f i ...
Page 274: ...8 16 Confidential Configuration List ...
Page 294: ...8 36 Confidential 1st sheet 2nd sheet Vertical Alignment Check Patterns ...
Page 297: ...8 39 Confidential Margin Check Pattern ...
Page 311: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 362: ...App 1 2 Confidential 2 Head property label Property label for the head carriage unit Location ...
Page 430: ......
Page 431: ......
Page 432: ......
Page 436: ......
Page 437: ......
Page 466: ...Confidential February 05 SM FAX028 8CA811 8 Printed in Japan ...