![Brooks SLA5800 Series Supplemental Manual Download Page 95](http://html1.mh-extra.com/html/brooks/sla5800-series/sla5800-series_supplemental-manual_2818721095.webp)
Installation and Operation Manual
X-DPT-DeviceNet-SLA5800-SLAMf-Series-RevB-PC-eng
Part Number: 541B0200AAG
March, 2015
81
Section 7 - Appendix
Brooks DeviceNet PCs
7. Appendix
7.1. Appendix A - Assembly Object Detail
The following table details each of the Assembly Objects supported by the
PC. The DeviceNet specification defines Input and Output relative to the
network (i.e. The data being PRODUCED from the device as an INPUT into
the network or the data being CONSUMED by the device is an OUTPUT
from the network).
Table 7-1 Summary Table of Input Assemblies
Instance ID
Data Description
Size(bytes)
Data Type
1 Pressure
2 INT
2 Status,
Pressure
3 INT
3
Status, Pressure, Valve
5
INT
4
Status, Pressure, Setpoint
5
INT
5
Status, Pressure, Setpoint, Valve
7
INT
6
Status, Pressure, Setpoint, Actuator Override, Valve
8
INT
13 Pressure
4 REAL
14 Status,
Pressure
5 REAL
15
Status, Pressure, Valve
9
REAL
16
Status, Pressure, Setpoint
9
REAL
17
Status, Pressure, Setpoint, Valve
13
REAL
18
Status, Pressure, Setpoint, Actuator Override, Valve
14
REAL
Table 7-2 Summary Table of Output Assemblies
Instance ID
Data Description
Size(bytes)
Data Type
7 Setpoint
2 INT
8
Actuator Override, Setpoint
3
INT
19 Setpoint
4 REAL
20
Actuator Override, Setpoint
5
REAL