Table 4-6 Supported Valve Parameters
EDS Parameter
Values
Description
EPATH
Valve Data Type
1,
2
Appendix B - Data Type
Definitions
The data type associated with reporting valve position.
[0x32-1-3]
Valve Data Units
1, 2
See the Actuator Units
Table Appendix C - Data
Units
The engineering units associated with reporting valve
position.
[0x32-1-4]
Valve Safe State
See Note: Valve Safe
State below
Configures the behavior of the valve when the device
is in Safe Mode.
[0x32-1-21]
Valve Override
3
See Note: Valve
Override below
Overrides the controller by commanding the valve to
one of the selectable values in the table below.
[0x32-1-5]
4.1.9.1. Valve Safe State Values
The following table outlines valid safe states for the valve. This table applies
for normally closed and normally open valves.
Table 4-7 Valve Safe State Values
Value State
Description
0
Closed
The valve will be driven closed and the valve position will
be 0% or 0 Counts
1
Open
The valve will be driven open and the valve position will
be 100% or Full Scale Counts Value
2
Hold Last Value
The valve will be driven to the last updated value just
prior to the entering of the safe state.
3
Use Safe Value
The valve will be driven to the value configured in the
Safe Value attribute of the S-Analog Actuator
1
This parameter is only configurable when the device is in the Idle State (i.e. when the device is not being actively scanned/polled).
2
This parameter will automatically be set based upon the inferred data type of the selected Assembly used for I/O (i.e. if an Assembly is
selected that reports valve position, and the inferred data type of the assembly is INT, then this attribute will be automatically set to INT once
I/O data exchange begins)
3
This Override action only occurs when the device is in the Executing State.