Installation and Operation Manual
X-DPT-DeviceNet-SLA5800-SLAMf-Series-RevB-PC-eng
Part Number: 541B200AAG
March, 2015
61
Section 5 - Detailed Configuration
Brooks DeviceNet PCs
Attrib
ID Name
Data
Type
Access
Rule NV
Description
Notes
9 Warning
Enable
BOOL
Set
NV
Enables the display of the
warning status bits
See Note: Warnings below
0 = disable [default]
1 = enable
10
Full Scale
Specified by
Attrib. 3 & 4
Get
NV
The pressure value that
represents 100% of the currently
selected calibration full scale
See Note ‘Full Scale’ below
17 Alarm
Trip
Point High
Specified by
Attrib. 3 & 4
Set NV
Determines
the Pressure[6] value
above which an Alarm Condition
will occur
See ‘Note: Alarms’ below
[default] = Maximum value
for its data type
18 Alarm
Trip
Point Low
Specified by
Attrib. 3 & 4
Set NV
Determines
the Pressure[6]
Value below which an Alarm
Condition Will occur
See ‘Note: Alarms’ below
[default] = Minimum value
for its data type
20 Alarm
Settling
Time
UINT Set
NV
Determines the time that the
Pressure[6] value must exceed
the Trip Point before the
exception condition is generated.
See ‘Note: Alarms’ below
Time in milliseconds
0 = [default]
21 Warning
Trip Point
High
Specified by
Attrib. 3 & 4
Set NV
Determines
the Pressure[6] value
above which a Warning Condition
will occur
See ‘Note: Warnings’ below
[default] = Maximum value
for its data type
22 Warning
Trip Point
Low
Specified by
Attrib. 3 & 4
Set NV
Determines
the Pressure[6] value
below which a Warning Condition
will occur
See ‘Note: Warnings’ below
[default] = Minimum value
for its data type
24 Warning
Settling
Time
UINT Set
NV
Determines the time that the
Pressure[6] value must exceed
the Trip Point before the
exception condition is generated.
See ‘Note: Warnings’ below
Time in milliseconds
0 = [default]
25 Safe
State USINT
Set
NV
Specifies the behavior of the
value reported for Pressure[6]
when the device is in an
Operational State other than
Executing State
See Note ‘Safe State’
below