53-1004106-15 Installation Guide
Brocade
®
X6-4 Director Hardware Installation Guide
Fan Direction: Non-portside Intake
Header Version: 2
Power Consume Factor: 2870w
Factory Part Num: 23-0000161-01
Factory Serial Num: DUC2M32L06L
Manufacture: Day: 10 Month: 8 Year: 2015
Update: Day: 16 Month: 2 Year: 2016
Time Alive: 88 days
Time Awake: 3 days
ID:
FAN Unit: 1
Fan Direction: Non-portside Intake
Header Version: 2
Power Consume Factor: -300w
Factory Part Num: 60-1003203-03
Factory Serial Num: DYL0329L05J
Manufacture: Day: 3 Month: 10 Year: 15
Update: Day: 16 Month: 2 Year: 2016
Time Alive: 88 days
Time Awake: 3 days
ID:
(output truncated)
WWN Unit: 1
System AirFlow: Non-portside Intake
Header Version: 2
Power Consume Factor: -1W
Factory Part Num: 60-1003194-02
Factory Serial Num: DZH0331L039
Manufacture: Day: 3 Month: 10 Year: 15
Update: Day: 0 Month: 0 Year: 0
Time Alive: 24 days
Time Awake: 0 days
ID: ***(@*%)(*
Part Num: ***(@*%)(*@#%(@*%)@*
Serial Num: ***(@*%)(*@#%(@*%)@*
Revision Num: ***(
(output truncated)
Chassis Factory Serial Num: DZB1339A006
errDump and errShow
Use the
errShow
command to display device error log messages one at a time. Use the
errDump
command to display
error log messages without any page breaks. The output of these commands are unique for each Control Processor (CP),
so must be executed on each CP blade to obtain a complete record.
Following is a partial example of
errDump
output.
chassisX6:admin> errdump
2016/03/28-08:44:28,[FV-1001], 90, SLOT 1 CHASSIS,INFO,My_Switch,Flow Vision daemon initialized.