53-1004106-15 Installation Guide
Brocade
®
X6-4 Director Hardware Installation Guide
70 4 6 014600 id N32 Online FC F-Port 21:00:00:24:ff:90:55:9e
71 4 7 014700 id N32 Online FC F-Port 21:00:00:24:ff:90:55:9f
72 4 8 014800 id N32 Online FC E-Port 10:00:00:27:f8:f2:c5:b8
73 4 9 014900 id N32 Online FC E-Port 10:00:00:27:f8:f2:c6:b8 "ras010" (Trunk master)
74 4 10 014a00 id N32 Online FC E-Port 10:00:00:27:f8:f2:c7:b8 "ras010" (Trunk master)
75 4 11 014b00 id N32 Online FC E-Port 10:00:00:27:f8:f2:c8:b8 "ras010" (Trunk master)
(output truncated)
tempShow
Use the
tempShow
command to display temperature readings of blade temperature sensors. The command displays the
following information:
•
Sensor ID (an index number)
•
Slot number
•
Sensor index (when command issued with the
--detail
option)
•
Sensor state (OK or absent)
•
Temperature in both Centigrade and Fahrenheit
The following is an example of
tempShow
output:
chassisX6-4:admin> tempshow
Sensor Slot Sensor State Centigrade Fahrenheit
ID Index
===================================================================
1 3 0 Ok 29 84
2 3 1 Ok 47 116
3 3 2 Ok 43 109
4 4 0 Ok 34 93
5 4 1 Ok 53 127
6 1 0 Ok 36 96
(output truncated)
Note the following facts about this output:
•
The absent state simply reflects that the blade slot is empty.
•
The sensor index is mainly for support use.
•
Multiple sensors are commonly averaged to determine thresholds used for managing fan speeds or for determining a
high temperature condition that may require that the blade be shut off.
Running Diagnostic Tests
Diagnostic tests are automatically run during POST to check the status of the device. Any error messages generated
during POST are sent to the error logs and to the serial console if the console is connected.
Diagnostic tests can also be run manually to test and troubleshoot the hardware and the firmware, including internal
connections and circuitry, transceivers, and port cables. However, diagnostic tests are generally intended for use by
support personnel.
NOTE
Error messages do not necessarily indicate that the device requires maintenance.
Each diagnostic test can be implemented by entering the related command through a telnet or serial session. For a list of
diagnostic tests and commands, refer to the
Brocade Fabric OS Administration Guide
.
53-1004106-15
102
Summary of Contents for Brocade X6-4
Page 208: ......