53-1004106-15 Installation Guide
Brocade
®
X6-4 Director Hardware Installation Guide
NOTE
To remove a power cord from an HVAC/HVDC power supply, you must first remove the power cord
retainer cover, if attached under the power cord connector. Then unlatch the power cord release latch that
is located under the power cord connector.
•
If you can leave the chassis in operation to replace a power supply, unplug the power cord from the power supply
assembly that you are replacing.
NOTE
Be sure to replace the power supply as soon as possible.
3. Loosen the captive screw on the right side of the power supply assembly until the screw releases from the chassis.
The captive screw is located just below the airflow label on the right side of the power supply assembly. If necessary,
use a Phillips screwdriver.
4. Grasp the handle and pull, sliding the power supply from the chassis and supporting the power supply from beneath as
you remove it.
Figure 65: Removing and Installing a Power Supply Assembly
5. If you are not replacing the power supply and can leave the chassis operating, insert a filler panel into the slot and
tighten the captive screw to secure to chassis.
This completes the procedure for removing a power supply.