Aesculap
®
TSPACE
®
PEEK/TSPACE
® XP
/TSPACE
®
3D
Instruments
Legend
A
Insertion instrument SN305R (assembled)
B
Insertion instrument SN305R (disassembled):
1
Tube
2
Switch
3
Rotary nut
4
Irrigation connector
5
Pin
6
Rod
7
Dihedron
C
Impact cylinder SN320R
D
Trial implant
E
Filling holder SN304R
Contents
1.
About this document. . . . . . . . . . . . . . . . . . . 2
1.1
Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2
Safety messages. . . . . . . . . . . . . . . . . . . . . . . 4
2.
Clinical use . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1
Areas of use and limitations of use . . . . . . . 4
2.1.1
Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1.2
Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1.3
Contraindications . . . . . . . . . . . . . . . . . . . . . 4
2.2
Safety information. . . . . . . . . . . . . . . . . . . . . 4
2.2.1
Clinical user . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2.2
Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2.3
Sterility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.3
Application . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.3.1
Preparing the implant bed . . . . . . . . . . . . . . 5
2.3.2
Determining the implant height with the
trial implant . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.3.3
Inserting the implant in the implant bed . . 7
3.
Validated reprocessing procedure . . . . . . . . 8
3.1
General safety information . . . . . . . . . . . . . . 8
3.2
General information . . . . . . . . . . . . . . . . . . . 9
3.3
Reusable products . . . . . . . . . . . . . . . . . . . . . 9
3.4
Preparations at the place of use. . . . . . . . . . 9
3.5
Preparing for cleaning . . . . . . . . . . . . . . . . . . 9
3.6
Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.7
Cleaning/Disinfection . . . . . . . . . . . . . . . . . . 10
3.7.1
Product-specific safety information on the
reprocessing method . . . . . . . . . . . . . . . . . . 10
3.7.2
Validated cleaning and disinfection
procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.8
Manual cleaning/disinfection . . . . . . . . . . . 11
3.8.1
Manual cleaning with immersion
disinfection . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.8.2
Manual cleaning with ultrasound and
immersion disinfection . . . . . . . . . . . . . . . . 13
3.9
Mechanical cleaning/disinfection . . . . . . . . 14
3.9.1
Mechanical alkaline cleaning and thermal
disinfection . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.10
Mechanical cleaning/disinfection with
manual pre-cleaning . . . . . . . . . . . . . . . . . . 15
3.10.1 Manual pre-cleaning with a brush . . . . . . . 15
3.10.2 Manual pre-cleaning with ultrasound and
brush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.10.3 Mechanical alkaline cleaning and thermal
disinfecting . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.11
Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.11.1 Visual inspection . . . . . . . . . . . . . . . . . . . . . 17
3.11.2 Functional test . . . . . . . . . . . . . . . . . . . . . . . 18
3.12
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.13
Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.14
Steam sterilization . . . . . . . . . . . . . . . . . . . . 18
3.15
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.
Technical service . . . . . . . . . . . . . . . . . . . . . 18
5.
Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.
Symbols on product and packaging . . . . . . 19
1.
About this document
Note
General risk factors associated with surgical procedures
are not described in these instructions for use.