Activate switch
to enable online
calibration
Performing the online offset calibration
DDU 8 has to be connected to RaceCon to calibrate the sensor’s offset.
1. Apply the desired physical condition to the sensor (e.g. 1 G to an acceleration
sensor).
2. Open the measurement channel’s online page by double‐clicking on the
measurement channel name in the Data Area.
3. Enter the physical target value (e.g. 1 G) and press the ‘Calibrate’ button.
Calibration
target value
Initiate
calibration
The sensor’s offset is now calibrated.
Group adjustment
Group adjustment is the simultaneous online calibration of several channels. This
is useful e.g. to set all wheel forces and damper positions to ‘0’ when the vehicle
is positioned on a flat patch.
Configuration of group adjustment
Group adjustment consists of two components:
▪ An input channel which triggers the adjustment event
▪ A group of input channels linked to the group adjustment event
Setting up the group adjustment trigger channel
1. Click ‘Measurement Sources’ in the Toolbox.
2. Drag the ‘Group Adjustment Channel’ element from the Toolbox and drop it
on the DDU 8
11.3.2
11.4
11.4.1
11.4.2
11 | Online Measurement