6. Enter channel name and description.
7. Click ‘Ok’ when done.
The channel is inserted into the DDU 8 Project Tree.
Calculation of
physical value with
characteristic curve
Input pin
Pull-up
resistor is
activated
Channel
is linked
to
ANA03
Available measurements for channel:
Measurement label
Function
raw_name
mV value of sensor
raw_name_fi
filtered mV value of sensor
name
physical value of sensor
name_fi
filtered physical value
Configuring a generic linear sensor
Example: Acceleration sensor 5 g
From sensor data sheet – operating characteristics:
Sensitivity 400 mV/g, Offset 2500 mV
The sensor has a linear output signal with sensitivity and offset
1. Click on ‘Measurement Sources’ in the Toolbox.
2. Expand the list of ‘I/O Channels’ by clicking on ‘+’ in the DDU 8 Project Tree.
10.3.2
Analog and Frequency Inputs | 10
Bosch Motorsport
DDU 8 Manual
73 / 160