Select physical unit.
Physical
(channel)
value
Choose ‘Ohm’ to enter
datasheet values directly.
Enter
resistance/temperature
pairs from sensor datasheet
here (The 3.01 kOhm pullup-
resistor is automatically
taken into account)
6. Click ‘Next’ when done.
The third part of the ‘Characteristic Curve Wizard’ opens.
Enter physical limits
of the channel
Choose data type of the
measurement variable
This sensor does not
need offset calibration
Physical
limits of
channel
Enter name to
automatically create a new
measurement sheet
Notice
Working with automatically created measurement sheets is ex-
plained in chapter ‘
Setting up an online measurement [
}
92]
’.
7. Click ‘Finish’ when done.
8. Enter channel name and description.
9. Click ‘OK’ when done.
The channel is inserted into the DDU 8 Project Tree.
Input pin
Pull-up
resistor is
activated
Characteristic
curve for
sensor
Adjustment
is disabled
Channel is
linked to
ANA05
Available measurements for channel:
Analog and Frequency Inputs | 10
Bosch Motorsport
DDU 8 Manual
77 / 160