Online Measurement
DDU 8 configuration
▪ System configuration (c display configuration, CAN I/O, PWM Out,
etc.) is stored in the DDU 8
▪ Use RaceCon to create and download configuration from the PC to DDU 8
▪ Communication interface: Ethernet
▪ Communication protocol: XCP
Online measu calibration
▪ System status and diagnosis
▪ Check and calibrate sensors in the vehicle
▪ Live display of sensor values on the PC
▪ Use RaceCon for diagnosis, online measurement and calibration
▪ Communication interface: Ethernet
▪ Communication protocol: XCP
Achieving an online connection
Set up the PC for access to the Unit
1. Switch off local firewall on the PC.
2. Set IP Configuration for the Ethernet interface to ‘automatic configuration’
(DHCP). See chapter ‘
Setting up the network interface [
}
17]
’ for details.
3. Start RaceCon.
4. Establish the Ethernet connection to the vehicle.
5. Power on the vehicle.
Status
message
window
Click ‘OK’ to
download RaceCon
configuration to
device
Yellow dot indicates
live connection to the
device, but local
RaceCon
configuration does
not match the DDU
8’s configuration