Recording diagnosis
The channel ‘statectrl_ok’ of the DDU 8 can be used for online monitoring of re‐
cording status.
Bit
Value
Name
0
1
RECORD
1
2
DATAOK
2
4
BLKOK
3
8
‐
4
16
‐
5
32
‐
6
64
STARTED
7
128
‐
Content of status bits
Name
Bitset
Bit cleared
RECORD
Measurement data is
recorded.
No measurement data will be stored because
measurement thresholds are not reached.
DATAOK
Received data without
error.
Discarding received data because of wrong
timestamps. Check wiring of SYNC signal.
BLKOK
All measurement
blocks have been set
up correctly.
Some measurement blocks have not been set
up correctly.
STARTED
A measurement has
been set up.
A measurement is not set up. Either no record‐
ing configuration has been found or logger
software upgrade is not activated.
Displaying online recording diagnosis
("statectrl_ok")
1. To add a Recording Diagnosis element to a measurement sheet, drag a ‘Bit‐
LED’ element from the Toolbox and drop it on measurement sheet.
2. Drag channel ‘statectrl_ok’ from the Data Area and drop it on the ‘Bit‐LED’ el‐
ement.
13.2.5
13.2.6
13 | Recording and Telemetry
116 / 160
DDU 8 Manual
Bosch Motorsport