Choose output frequency
Define characteristic curve
Choose input
channel
Enter name to
automatically create a new
measurement sheet
Notice
Working with automatically created measurement sheets is ex-
plained in chapter ‘
Setting up an online measurement [
}
92]
’.
Notice
Choosing a filtered channel as an input for ‘PWM_OUT’ will
cause delayed reaction due to the delay introduced by the digi-
tal filter.
Use unfiltered values for this purpose.
Notice
The ‘power-on’ state of the PWM output is ‘switch open’ (0%
duty cycle).
4. Click ‘Finish’ when done.
5. Enter channel name and description.
6. Click ‘OK’ when done.
The channel is inserted into the DDU 8 Project Tree.
Characteristic
curve
Output
frequency
Channel is
linked to
PWM_OUT02
Measurement
channels
Measurement label
Function
pwm_err_ls_out_01_OL
PWM output 1 error open load
pwm_err_ls_out_01_OT
PWM output 1 error over temperature
pwm_err_ls_out_01_SCB
PWM output 1 error short circuit to battery
Analog and Frequency Inputs | 10
Bosch Motorsport
DDU 8 Manual
89 / 160