3. Drag the ‘Sensitivity/Offset’ analog signal source from the Toolbox and drop
it on the desired analog input channel in the DDU 8 Project Tree. A ‘Sensitivi‐
ty/Offset Wizard’ opens.
4. To activate the internal pullup‐resistor, check the box.
The internal pullup‐resistor is used to get a 5 V signal at the analog channel
of the DDU 8.
It allows you to use a push‐button.
The fixed value of the internal pullup‐resistor is 3010 Ohm. If using an addi‐
tional external pullup‐resistor, set up the overall resistance.
5. Click ‘Next’ when done.
The second part of the ‘Sensitivity/Offset Wizard’ opens.
Choose unit
group and unit
of physical value
Enter values
from sensor
datasheet
Electrical
(pin) value
Physical
(channel)
value
6. Click ‘Next’ when done. The third part of the ‘Sensitivity/Offset Wizard’
opens.
10 | Analog and Frequency Inputs
74 / 160
DDU 8 Manual
Bosch Motorsport