The system is counting:
Outing:
▪ The outing counter is incremented with each power cycle when at least one
valid lap (not by forced lap trigger) was recorded
Lap:
▪ Leaving the pits to lap trigger
▪ Lap trigger to lap trigger
▪ Enforced lap trigger (see Distance based forced trigger)
Fragment:
▪ Test bench operation
▪ Power cycle on track or box (e.g. engine stalled)
▪ File fragmentation size [MB], time [sec]
Channels for display
To display counters use the following channels:
Channel
Function
Laptrigger_outcnt_dls
Outing counter
Laptrigger_lapctr_dls
Lap counter
Fractr
Fragment counter
Counting in WinDarab
To automatically name recorded files use filename templates in WinDarab dialog:
Filename template
Function
[outing]
Value of outing counter
[lap]
Value of lap counter
[fragment]
Value of fragment counter
[###03] indicates: ‘always use 3 digits with leading zeros’.
Lap timing
There are different possibilities to adjust the lap trigger to the timing situation.
The detection time defines the minimum time the input signal changes its state.
E.g. a low active signal needs to be below the threshold for min. 15 ms to release
the trigger.
Channels for display
To display lap times use the following channels:
Channel
Function
Laptrigger_lapctr_dls
Number of completed laps
Laptrigger_laptime_dls
Running laptime
Laptrigger_laptime_best_dls
Laptime of best lap
14.3
Lap Trigger | 14
Bosch Motorsport
DDU 8 Manual
135 / 160