Display Unit DDU 7
Analog and Frequency Inputs | en
81
Bosch Motorsport
Manual
04.02.2019 | V 02 |
Notice!
Working with automatically created measurement sheets is explained in chapter ‘
Setting up an
online measurement, page 97
’.
7.
Click ‘Finish’ when done.
8.
Enter channel name and description.
9.
Click ‘OK’ when done.
The channel is inserted into the DDU 7 Project Tree.
Input pin
Pull-up
resistor is
deactivated
Sensitivity
and Offset
value for
sensor
Adjustment
is enabled
Channel is
linked to
ANA04
Available measurements for channel:
Measurement label
Function
raw_name
mV value of sensor
raw_name_fi
filtered mV value of sensor
name
physical value of sensor
name_fi
filtered physical value
10.3.3
Configuring a generic non-linear sensor
Example: Thermistor 5 kOhm
–
From sensor data sheet: resistance values over temperature