14.2
Counting outing/laps/fragments
Functionality
–
Power ON: measurement is initialized but not yet started
–
Global start condition fulfilled: recording starts
–
Reception of valid lap trigger: recording of lap completed, new lap starts
–
Power OFF or Global start condition not fulfilled: recording of lap completed, system
shutdown
The system is counting:
Outing:
–
The outing counter is incremented with each power cycle when at least one valid lap (not
by forced lap trigger) was recorded
Lap:
–
Leaving the pits to lap trigger
–
Lap trigger to lap trigger
–
Enforced lap trigger (see Distance based forced trigger)
Fragment:
–
Test bench operation
–
Power cycle on track or box (e.g. engine stalled)
–
File fragmentation size [MB], time [sec]
Channels for display
To display counters use the following channels:
Channel
Function
Laptrigger_outcnt_dls
Outing counter
Laptrigger_lapctr_dls
Lap counter
Fractr
Fragment counter
Counting in WinDarab
To automatically name recorded files use filename templates in WinDarab dialog:
Filename template
Function
[outing]
Value of outing counter
[lap]
Value of lap counter
[fragment]
Value of fragment counter