Check box to enable online
offset calibration and enter
desired physical target value
In the channel view
Activate switch
to enable online
calibration
11.3.2
Performing the online offset calibration
DDU 7 has to be connected to RaceCon to calibrate the sensor’s offset.
1.
Apply the desired physical condition to the sensor (e.g. 1 G to an acceleration sensor).
2.
Open the measurement channel’s online page by double-clicking on the measurement
channel name in the Data Area.
3.
Enter the physical target value (e.g. 1 G) and press the ‘Calibrate’ button.
Calibration
target value
Initiate
calibration
The sensor’s offset is now calibrated.