64
en | CAN Bus
Display Unit DDU 7
04.02.2019 | V 02 |
Manual
Bosch Motorsport
9
CAN Bus
DDU 7 has two fully configurable CAN buses.
–
Baudrate (125 kBit to 1 MBit)
–
11 Bit or 29 Bit identifiers
–
Input configuration: Read messages from CAN bus and convert to DDU 7 measurement/
display variables. CAN bus supports row counter configuration.
–
Output configuration: Write DDU 7 measurement variables to CAN messages, output
frequency and row counter are configurable, CAN gateway functionality (transfer from
one bus to the other)
9.1
CAN bus trivia
CAN message
–
11 Bit (standard) or 29 Bit (extended) identifier
–
Up to 8 bytes of data payload
CAN bus
–
Needs termination resistors (120 Ohm) in wiring harness
–
All devices connected to the bus must use identical data rate
Configuration of DDU 7 bus data rate by double click on the CAN bus in project tree (1
MBaud, 500 kBit, 250 kBit, 125 kBit)
Row counter concept
–
Re-use (multiplex) of message identifiers
–
One byte of message contains row counter
–
7 bytes payload remaining
–
Position of row counter is configurable
Payload Area
Row
Counter
Row
Counter
Payload Area
Message
Id