84
en | Analog and Frequency Inputs
Display Unit DDU 7
04.02.2019 | V 02 |
Manual
Bosch Motorsport
Input pin
Pull-up
resistor is
activated
Characteristic
curve for
sensor
Adjustment
is disabled
Channel is
linked to
ANA05
Available measurements for channel:
Measurement label
Function
raw_name
mV value of sensor
raw_name_fi
filtered mV value of sensor
name
physical value of sensor
name_fi
filtered physical value
10.3.4
Configuring a multipoint adjustment
Example: Measurement of wheel force
–
Physical property ‘wheel force’ not directly measureable
–
Load transfer through suspension kinematics
–
Physical value at sensor position defined by vehicle
–
Curve definition by online adjustment at vehicle
1.
Click on ‘Measurement Sources’ in the Toolbox.
2.
Expand the list of ‘I/O Channels’ by clicking on ‘+’ in the DDU 7 Project Tree.
3.
Drag the ‘Multipoint Adjustment’ analog signal source from the Toolbox and drop it on
the desired analog input channel in the DDU 7 Project Tree.
4.
A ‘Multipoint Adjustment Wizard’ opens.
5.
To activate the internal pullup-resistor, check the box.
The internal pullup-resistor is used to get a 5 V signal at the analog channel of the DDU 7.
It allows you to use a push-button.
The fixed value of the internal pullup-resistor is 3010 ohm. If using an additional external
pullup-resistor, set up the overall resistance.