Display Unit DDU 7
Display Configuration | en
59
Bosch Motorsport
Manual
04.02.2019 | V 02 |
Example: Setting up a condition for maximum front brake pressure.
20
20
10
Max brake pressure of the variable ‘front p_br_front_mx’
Reset
value
is used
Hold
max.
value
Follow
max.
value
Reset
value
is used
Time
Time
Condition ‘p_br_front > 20’
Brake pressure front p_br_front
30
40
30
40
10
Brake pressure ‘front p_br_front’
Hold max.
value
Hold max.
value
Threshold
reached
–
At power-up, the reset value (10) is used for ‘p_br_front_mx’.
–
‘p_br_front’ rises to 30. As ‘p_br_front’ is > 20 (condition is TRUE), the condition ‘max
(p_br_front, p_br_front_mx)’ in the THEN window is triggered. The condition sets the
bigger value as new value for ‘p_br_front_mx’. As ‘p_br_front’ (30) is bigger than
‘p_br_front_mx’ (10), the new value for ‘p_br_front_mx’ is set to 30.
–
Although ‘p_br_front’ falls to 25, the value of ‘p_br_front_mx’ stays 30. This is caused by
the THEN-condition, because p_br_front_mx’ (30) is still bigger than p_br_front’ (25).
–
As ‘p_br_front’ rises to 40. As ‘p_br_front’ (40) is bigger than ‘p_br_front_mx’ (30), the
new value for ‘p_br_front_mx’ is set to 40.
–
As ‘p_br_front’ falls below 20, the IF-condition turns to FALSE. Now the OTHERWISE-
condition is triggered. Because the condition ‘p_br_front_mx’ sets the value of
‘p_br_front_mx’ and the value that is already set to 40 before, nothing changes.
–
When ‘p_br_front’ rises to 40, the If-condition changes to TRUE again and triggers the
THEN-condition. Now the reset value (10) is used for ‘p_br_front_mx’ in the THEN-
condition.
–
Because 40 is bigger than 10 the new value of ‘p_br_front_mx’ is 40.
8.6
Condition channels
Condition channel
–
Logical operations on measurement channel(s)
–
If-Else structure with reset
–
Logical result
–
Result can be used as input source for Alarm display elements and further calculations in
the whole RaceCon project.
Condition combination
–
Combination of several (up to 16) condition channels for more complex calculations
–
Logical results
All conditions can be used globally in the whole DDU 7 project.