Status word
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit
0
Ready to switch on
1
Switched on
2
Operation enabled
3
Fault
4
Voltage enabled
5
Quick stop (low active)
6
Switch on disabled
7
Warning
8
-
9
Remote
10
Target reached
11
Internal limit active
12
Speed
13
Max Slippage
14
-
15
Warning 2
The Profile Velocity Mode is used to set the reference speed in user units [u/s]. The
reference speed
0x60FF
Target Velocity
is taken over in mode “operation enabled”
immediately (0xnn37). The acceleration and deceleration ramp are specified by ob-
Setting Bit 8 “Halt” of the control word delays the drive with ramp
and holds the drive at standstill. Resetting Bit 8 results in an acceleration
with ramp
to the actual reference velocity.
Control word Bit 8: Halt
HALT = 0
Execute Profile Velocity Mode.
HALT = 1
Halt Axis. (The Frequency inverter remains in state “Operation
enabled”.)
The actual velocity in [u/s] can be displayed in a PLC via map able Object
184
CM-CAN ACU
04/13