5
Installation/Disassembly of the communication module
5.1
Installation
The communication module CM-CAN is pre-assembled in a case. Additionally, a PE
spring is enclosed for PE connection (shield).
Caution!
Danger of desytroying the frequency inverter and/or the communication
module
•
The frequency inverter must be disconnected from the power supply before
installation of the communication module. Assembly under voltage is not
permissible.
•
Do not touch the PCB visible on the back of the module, otherwise compo-
nents may be damaged.
Work steps:
•
Disconnect the frequency inverter from the mains voltage and protect it against
being energized unintentionally.
•
Remove covers (1) and (2) of the frequency inverter. Slot B (4) for the commu-
nication module is now accessible.
•
Mount the supplied PE spring (5) using the M4 screw (6) in the unit. The spring
must be aligned centrally.
•
Insert the communication module in slot B (4) until it engages audibly.
•
Fix the communication module by screwing the M2 screw (7) of the module to the
PE spring (5).
5
6
(M4)
8
7
(M2)
•
In the upper cover (1), break out the pre-punched cutout (3) for the plug X310
(8).
•
Mount the two covers (1) and (2).
24
CM-CAN ACU
04/13
Summary of Contents for Vectron Active Cube
Page 1: ...ACTIVE CUBE CANopen Communication module CM CAN Frequency inverter 230 V 400 V...
Page 2: ......
Page 239: ......