Getting Started
Remove the protective cover from the PC board.
Remove the insulating spacers from the holders of the main and backup batteries and wait until
depassivation is completed.
Figure 10-5
The depassivation procedure activates batteries after long term storage and can take up to 5 minutes.
The process of depassivation is indicated as shown in Table 10-6. If depassivation fails the detector
indication is similar to indication of low batteries (see Table 10-7).
Connecting and Programming
Connect the detector to the ARR32 and set its parameters in the configuration of the polling loop
controller as discussed in Sections 6, 7, and 8 of this Manual.
When the detector has been connected on the ARR32, put the protective cover on it.
In case of deep battery passivation (after storage for a longer than two years) a
passivation process can last up to four hours. In this process the device operates in the
quiescent mode and depassivation is started every 30 minutes until it has been
completed successfully.
Until depassivation succeeds the detector indicates discharged conditions of the main
battery (with transmitting the relevant state to the control and indicating equipment).
If upon expiry of four hours the battery condition has not yet been normalized then the
batteries must be replaced.