S2000R
Appendix A. Batteries
101
www.bolid.ru
A Link Quality Test is started by a short press on the Prog button (see Figure 10-24). The procedure
takes 60 seconds, the detector indicating the results of the test as shown in Table 10-54.
As testing link quality is in progress you can move the detector and the ARR32 to find the best
locations for them.
You can also estimate quality of the link using S2000R Configurator as discussed in Section 7.
Testing
Just after mounting, the S2000R-SHIK should be tested for proper working condition.
Ensure the detector is in normal state in accordance with system indication.
Trigger the detector by walking through the detection area.
Ensure that the detector indicates the intrusion alarm, and a relevant message is received by
control and indicating equipment.
Wait until the detector returns to normal state.
Test Mode
To inspect operability of the infrared sensor and to simplify selecting mounting location of the
detector, the test mode can be used.
In this mode the S2000R-SHIK provides an easy-to-see indication of activation of the infrared sensor
immediately, regardless of sending data over the radio channel.
To start and to exit test mode, perform the following combination of presses on the Prog button: three
times for a short time and once for a long time. Starting/exiting the test mode is accompanied with
the relevant indication (see Table 10-55).
Turning the test mode on and off can also be carried out by means of S2000R Configurator (see
Section 7).
Maintenance
Inspect operability of the S2000R-SHIK at least every 3 months.
If the S2000R-SHIK indicates low battery conditions, replace the battery.