S2000R
27
www.bolid.ru
Figure 7-7
To proceed to the 30 s poll interval mode run Configurator and briefly press the tamper switch on the
S2000R-ASR2 PC board down (see the relevant section of this Manual). The S2000R-ASR2 icon in
Device Area shall be highlighted in dark-green.
The S2000R-ASR2 quits the 30 s poll interval mode automatically in 10 minutes after exiting
Configurator.
Setting Properties of S2000R-IP and S2000R-DIP
Monitoring for tampering S2000R-IP and S2000R-DIP detectors can be activated/deactivated by
means of the right-click menu in Device Area (the menu commands Disable Tamper Monitoring and
Enable Tamper Monitoring).
Setting Properties of S2000R-RM
Specifying the main power supply for relay modules S2000R-RM is performed in the string Main
Power Supply on the Properties tab.
The main power supply can be Battery (if no 12 V power supply is connected to the module) or
External (provided that a 12 V power supply is connected).
This setting defines the content of messages transmitted to the polling loop controller when states of
the power supplies of the module change: