Serial Trigger and Decode
125
Protocol Config
To set the baud rate use the touchscreen to select Protocol Config:
1.
The
Manchester CONFIG
menu will be displayed. (Figure
??
)
2.
Use the touchscreen to select
Baud
.
–
Use the
Universal Rotary Knob
or the virtual keypad to set the baud rate, the
range is 500b/s to 5Mb/s
3.
Use the touchscreen to set
Polarity
to
R:1
or
F:1
.
–
R:1 indicates that rising edge is used to encode a bit value of logic 1.
–
F:1 indicates that falling edge is used to encode a bit value of logic 1.
4.
Use the touchscreen to set the
Idle Level
to
Low
or
High
.
5.
Use the touchscreen to select
Start Edge
.
–
Set the starting edge of the Manchester signal. The range is 1 to 32.
6.
Use the touchscreen to select
Idle Bits
.
–
Set the minimum idle time/inter-frame gap time of the Manchester bus in terms of
the bit width.
7.
Use the touchscreen to select
Display bits
.
–
Set the display format to Bye or Bit.
8.
Use the touchscreen to set the
Bit Order
to
LSB
or
MSB
.
9.
Use the touchscreen to select
Sync Size
.
–
Set the sync field size, from 0 to 32.
10.
Use the touchscreen to select
Header Size
.
–
Set the header size, from 0 to 32.
11.
Use the touchscreen to select
# of Words
.
–
Set the number of words in data field, from 1 to 255.
12.
Use the touchscreen to select
Word Size
.
–
Set the data word size, from 2 to 8
13.
Use the touchscreen to select
Trailer Size
.
–
Set the trailer size, from 0 to 32.
14.
Touch
option to return previous menu.
Figure 10.61
Manchester CONFIG