Serial Trigger and Decode
118
Note:
Protocol Copy
The signal settings of decoding and triggering are independent. To synchronize
the settings between decode and trigger select
1.
The
DECODE COPY
menu will be displayed. (Figure
2.
Use the touchscreen to select
Copy To Trigger
or
Copy From Trigger
.
3.
Copy To Trigger
copies the decode settings to trigger.
4.
Copy From Trigger
copies the trigger settings to decode.
5.
Touch
option to return previous menu.
The synchronization is not automatic. If the settings at one
place change, a copy operation is necessary to re-synchronize.
Figure 10.52
Decode Copy
10.10.2
SENT Trigger
To select
SENT Trigger
:
1.
Touch the
Trigger
dialog box to display the
Trigger
2.
Touch the
Type
option and select
Serial.
3.
Use the touch screen to select
Protocol
.
–
the dropdown menu shown in figure
??
will appear.
4.
Select
SENT
.
Signal
•
Use the touchscreen to select
Signal
.
•
Use the touchscreen to select
Source
and select the source the signal is connected to.
•
Use the touchscreen to select
Threshold
and input the desired threshold
–
The threshold voltage level is for decoding, and it will be regarded as the trigger
voltage level when the trigger type is set to serial.
–
The threshold level line only appears when adjusting the threshold level.
•
Touch
option to return previous menu.
Figure 10.53
SENT Trig-
ger