Page 24
8.1.2
Blade Removal Sequence (Continued)
•
Close the blades fully and lock the blade latch.
FIGURE #15
•
Disconnect the air line before proceeding.
FIGURE #16
FIGURE #17
•
Use a 1/2 inch wrench to unscrew the blade mounting screw until it becomes loose enough
to move in and out. This screw will remain captured by the blade set and will not fall out.
Do Not Attempt To Remove The Screw Completely.
FIGURE #18
Blades Closed
Latch Locked
Press Tab