![BETTCHER INDUSTRIES AirShirz Operating Instructions And Spare Parts List Download Page 24](http://html.mh-extra.com/html/bettcher-industries/airshirz/airshirz_operating-instructions-and-spare-parts-list_2743095024.webp)
OPERATING
BETTCHER
AIRSHIRZ
®
INSTRUCTIONS
INDUSTRIES, INC. Rev. September 24, 2016
Page 18
7.1
Configuration #1 - Permanent Mount to End of Air Supply Pipe (Continued)
Discard the male connector.
Shut off the air supply.
Build the air line so that it ends with 1/4 NPT male threads to a point 4 inches
(10 cm) from the desired AirShirz
®
plug-in point.
Apply a thread sealant to the male threads of the air supply line and mount the filter body
directly onto the pipe.
Turn on the air supply. The coupler is ready to use. (The AirShirz
®
filter/ coupler shuts
off automatically when it is disconnected from the power unit).
7.2
Configuration #2 - Mount to Air Hose or Pipe with Standard Quick Disconnect
Shut off the air supply.
Confirm that
your
quick connect female coupler mates properly with the male connector of
the AirShirz
®
filter/coupler assembly.
Mount your female coupler to the end of a pipe or flexible air hose and run this pipe or
hose to a point 4.5 inches (11 cm) from the desired AirShirz
®
plug-in point.
Turn on the air supply.
Connect the AirShirz
®
filter/coupler. It is ready to use.
When the AirShirz
®
is disconnected, it should be done at the small coupler on the coiled
tubing.
CONFIGURATION #2
EXHAUST
4 1/2 “
AIRSHIRZ®
FILTER/COUPLER
CUSTOMERS STANDARD
DISCONNECT
PIPE OR
FLEXIBLE TUBING
PRESSURE
REGULATOR
AIR FILTER
REPLACEMENT
ELEMENT
AIR SUPPLY