![BERGHOF B-PRIMIS DC-PRIME DC2110W X CM User Handbook Manual Download Page 67](http://html.mh-extra.com/html/berghof/b-primis-dc-prime-dc2110w-x-cm/b-primis-dc-prime-dc2110w-x-cm_user-handbook-manual_2737010067.webp)
USER HANDBOOK 1.2 | B-PRIMIS DC/ET PRIME 2110W X C, 2115WUX C
Berghof Automation GmbH | Harretstraße 1 | 72800 Eningen | www.berghof-automation.com
270011X00_B-PRIMIS_ET-DC-PRIME 2110W-2115W_EN.docx
67
Dialog Controller
DC2115WUX CM
DC2110W X CM
Shock resistance
Vibration
sinusoidal (EN 60068-2-
6) test: Fc 10…150 Hz, 10 m/s²
Shock
15 G (approx. 150 m/s²), 11 ms duration, sinusoidal half-wave (EN
60068-2-27)
Test: Ea
EMC, protection rating
Emitted interference
EN 61131-2; EN 61000-6-3, residential areas
Resistance to interference
EN 61131-2, industrial zone
Protection class
III
Insulation resistance
EN 61131-2; 500 V DC test voltage
Protection rating
IP20 (front IP44)
Power supply (24 V power)
Supply voltage
+24 V DC (
–15 % / +20 %) SELV max. ripple component 5%
Power consumption
Max. 0.8 A, peak current 1.2 A at +24 V DC fused
Power consumption, dig. Out-
puts
Depending on the output load, max. 2 A continuous rating
Protection against reverse po-
larity
yes
Ethernet interfaces
No. / type of interface
1x 10/100 Base T
Connection system
RJ45
EtherCAT interface
No. / type of interface
1x EtherCAT (EtherCAT master)
Connection system
RJ45
CAN bus interface
No. / type of interface
1x CAN-Bus (optional)
Protocols
CAN-Bus and/or CANopen master (optional)
Serial interfaces
No. / type of interface
1x RS-232 (optional);
1x RS-485 (optional)
Protocols
Modbus RTU (optional)
USB interfaces
No. / type of interface
2 x host USB 2.0 / USB connector port A
No. plugging/unplugging cycles
max. 1000