345
Maintenance
10
Maintenance
This chapter explains how to replace the cooling fan, the regular inspections to complete, and how
to store and dispose of the product. An inverter is vulnerable to environmental conditions and faults
can also occur due to component wear and tear. To prevent breakdowns, please follow the
maintenance recommendations in this section.
•
Before you inspect the product, read all safety instructions contained in this manual.
•
Before you clean the product, ensure that the power is off.
•
Clean the inverter with a dry cloth. Do not use wet cloths, water, solvents, or detergents. This
may result in electric shock or damage to the product.
Regular Inspection Lists
Daily Inspections
Inspection
area
Inspection item
Inspection
details
Inspection method Judgment
standard
Inspection equipment
All
Ambient
environment
Is the
ambient
temperatur
e and
humidity
within the
design
range, and
is there any
dust or
foreign
objects
present?
Refer to 1.3
Installation
Considerations
on
page
4
.
No icing
(ambient
temperatur
e: -10 - +40)
and no
condensatio
n (ambient
humidity
below 50%)
Thermometer,
hygrometer,
recorder
Inverter
Is there any
abnormal
vibration or
noise?
Visual inspection
No
abnormality
Power voltage
Are the
input and
output
voltages
normal?
Measure voltages
between R/ S/ T-
phases in. the
inverter terminal
block.
Refer to 11.1
Drive
Ratings
.
Digital multimeter
tester
Summary of Contents for Rsi S Series
Page 2: ......
Page 6: ......
Page 12: ...Preparing the Installation 0...
Page 22: ...Preparing the Installation 10...
Page 70: ...LearningAdvanced Features 58...
Page 152: ...LearningAdvanced Features 140 PID controlblock diagram...
Page 224: ...LearningAdvanced Features 212...
Page 356: ...344...
Page 362: ...Maintenance 350...
Page 381: ...369 TechnicalSpecification...
Page 397: ......