Learning Advanced Features
198
Analog Pulse Output
Select 1 of 15 functions with parameter OU.01, Analog Output1 to be represented by the pulsed
output. Note the Q1 terminal must be set to TO, Pulse Output.
G
r
o
u
p
Code Name
LCD Display
Parameter Setting
Setting Range
Unit
O
U
33
Multi-function output 1
Q1 define
39
TO
0–38
-
61
Pulse output setting
TO Mode
0
Frequency
0–15
-
62
Pulse output gain
TO Gain
100.0
-1000.0–1000.0
%
63
Pulse output bias
TO Bias
0.0
-100.0-100.0
%
64
Pulse output filter
TO Filter
5
0–10000
ms
65
Pulse output constant
output2
TO Const %
0.0
0.0-100.0
%
66
Pulse output monitor
TO Monitor
0.0
0.0–1000.0
%
Analog Pulse Output Setting Details
Code
Description
OU.33 Q1 Define
In case of Standard I/O, pulse output TO and multi-function output Q1 share
the same terminal. Set OU.33 to TO which represents a 32kHz pulse output
and follow the instructions below to make wiring connections that configure
the open collector output circuit.
1.
Connect a 1/4W, 560
Ω
resistor between VR and Q1 terminals.
2.
Connect EG and CM terminals.
When wiring the resistor, a resistance of 560
Ω
or less is recommended to
stably provide 32kHz pulse output.
Summary of Contents for Rsi S Series
Page 2: ......
Page 6: ......
Page 12: ...Preparing the Installation 0...
Page 22: ...Preparing the Installation 10...
Page 70: ...LearningAdvanced Features 58...
Page 152: ...LearningAdvanced Features 140 PID controlblock diagram...
Page 224: ...LearningAdvanced Features 212...
Page 356: ...344...
Page 362: ...Maintenance 350...
Page 381: ...369 TechnicalSpecification...
Page 397: ......