Environmental Manager
125
Table 10-1. Pin out of the ASG Guard Plus Environmental Manager
PIN NUMBER
Telco Color Code*
Function
1
WH/BLUE
Sensor #1
26
BLUE/WH
Ground
2
WH/ORN
PLUS 5 V
27
ORN/WH
GROUND
3
WH/GRN
SENSOR #2
28
GRN/WH
GROUND
4
WH/BRN
PLUS 5 V
29
BRN/WH
GROUND
5
WH/SLT
SENSOR #3
30
SLT/WH
GROUND
6
RE/BLUE
PLUS 6 V
31
BLUE/RE
GROUND
7
RE/ORN
TEMPERATURE SENSOR
32
ORN/RE
GROUND
8
RE/GRN
PLUS 5 V
33
GRN/RE
GROUND
9
RE/BRN
PBX B
34
BRN/RE
PBX BATTERY -
10
RE/SLT
PLUS 5V
35
SLT/RE
GROUND
11
BLK/BLUE
NOT USED
36
BLUE/BLK
NOT USED
12
BLK/ORN
NOT USED
37
ORN/BLK
NOT USED
13
RE/GRN
CONTACT CLOSURE #1
38
GRN/RE
CONTACT CLOSURE #1
14
RE/BRN
CONTACT CLOSURE #2
39
BRN/RE
CONTACT CLOSURE #2
15
RE/SLT
CONTACT CLOSURE #3
40
SLT/RE
CONTACT CLOSURE #3
16
YL/BLUE
CONTACT CLOSURE #4
Summary of Contents for Lucent Technologies Access Security Gateway Guard
Page 12: ...x Page intentionally left blank ...
Page 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Page 36: ...Physical Connections 24 Page intentionally left blank ...
Page 60: ...Modem Port Setup 48 Page intentionally left blank ...
Page 82: ...Modifying the User Database 70 Page intentionally left blank ...
Page 120: ...Action and Event Tables 108 Page intentionally left blank ...
Page 158: ...User Connectivity 146 Page intentionally left blank ...
Page 188: ...Log Functions 176 Page intentionally left blank ...
Page 236: ...Troubleshooting 224 Page intentionally left blank ...
Page 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Page 258: ...Glossary of Command References 246 Page intentionally left blank ...