Action and Event Tables
103
8.7.3 Delete Alarm/Event – XE Command
The Delete Alarm/Event command allows you to remove a pending action from the Event Table.
An access class of Sysop 2 or higher is required.
Type XE at the system prompt and press the ENTER key to display the Delete Alarm/Event
screen. The system will then display the parameters for that alarm/event, with the cursor
appearing at the first parameter.
>XE
--- Delete Alarm/Event ---
Current Date: 10/10/93 Time: 09:15:36
1) .HOURLY 10/10/93 08:00:01
PHONHOME (ASAP)
2) SYSOP GENERATED 10/10/93 09:00:02
PHONHOME (ASAP)
3) .CDR.REGIONAL_CALLS,001,0004,Max Call/Hr 10/07/93 09:37:21
PAGE (ASAP) ,9990010004
Select # -> (ENTER for more, * for all, Ctrl-A to quit)
Screen 8-10. Delete Alarm/Event Screen
The Event Table is updated immediately as changes are made to it. To delete an entry in the
table, enter the number corresponding to that entry at the
Select # -
prompt, then press the
ENTER key.
NOTE:
The entire Event Table may be cleared by typing an asterisk (*) instead of a number.
The system then displays the line for that action item and asks if you want to delete that record.
Initially, a No appears in the field. Press the SPACE BAR to toggle the field to Yes and then
press the ENTER key. The system confirms that you have deleted the record.
Select # -> 2 (ENTER for more, * for all, Ctrl-A to quit)
SysOp Generated 10/10/93 09:00:02
PHONHOME (ASAP)
Delete Record ? Yes
>10/10/93 09:16:12 [M] SysOp Generated Alarm/Event deleted
>
Screen 8-11. Delete Record Screen
Summary of Contents for Lucent Technologies Access Security Gateway Guard
Page 12: ...x Page intentionally left blank ...
Page 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Page 36: ...Physical Connections 24 Page intentionally left blank ...
Page 60: ...Modem Port Setup 48 Page intentionally left blank ...
Page 82: ...Modifying the User Database 70 Page intentionally left blank ...
Page 120: ...Action and Event Tables 108 Page intentionally left blank ...
Page 158: ...User Connectivity 146 Page intentionally left blank ...
Page 188: ...Log Functions 176 Page intentionally left blank ...
Page 236: ...Troubleshooting 224 Page intentionally left blank ...
Page 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Page 258: ...Glossary of Command References 246 Page intentionally left blank ...