2022.3-0000010 OM
247
1- bolt; 2- condenser; 3, 4- brackets; 5 – filter drain; 6 -fitting piece.
Figure 6.4.6 – Air conditioner condenser uplift
CORROSIVE DETERGENT COMPOSITIONS SHALL NOT BE USED!
6.4.1.14 Operation 13. Check/cleaning of the engine water radiator and the en-
gine CAC-radiator
Check cleanliness of the hood mask, engine CAC-radiator core and engine water
radiator. In case it is clogged, do the following actions:
- uplift the air conditioner condenser as it is stated in clause 6.4.1.13;
- carry out CAC-radiator cleaning with compressed air. Direct the air flow perpen-
dicular to the CAC-radiator plane from top downward. In case of severe CAC-radiator
clogging, rinse it with hot water under pressure of not more than 0.2 MPa and blow it off by
compressed air;
- put the air conditioner condenser back to its place;
- carry out water radiator cleaning with compressed air. Direct the air flow perpen-
dicular to the water radiator plane from top downward. In case of severe water radiator
clogging, rinse it with hot water under pressure of not more than 0.2 MPa and blow it off by
compressed air;
- radiator cores shall be cleaned both from the hood mask side and from the engine
fan side.
ALKALINE SOLUTIONS AND CORROSIVE DETERGENT COMPOSITIONS
SHALL NOT BE USED!
.
https://tractormanualz.com/