77
R5906852 /09
F80
How to properly display HDR content?
If your provided HDR content has been mastered with PQ (e.g. HDR10 and Dolby Vision), a few changes can
be made in order to project the intended mastering on screen. These changes are necessary because HDR
content has been mastered specifically for HDR capable displays that are watched in living rooms. These
conditions are different from a non-HDR projector and darker cinema-like environments.
The projected HDR content depends on the following factors:
•
Mastering luminance
: This is content-specific and cannot be changed.
•
Screen luminance
: Every projection screen has a specific luminance (measured in nits or foot-Lambert).
Entering this luminance in the projector will adapt the content towards the intended HDR result.
•
HDR Boost
: A variable “booster” that may amplify or downplay the HDR output.
How to set the HDR-related parameters?
1.
Make sure the chosen Gamma Type is set to
AUTO
. For more info, refer to
.
2.
In the main menu, select
Image
→
Advanced
→
HDR
.
Image 7–35 Advanced settings menu, HDR
The HDR menu is displayed.
Image 7–36 Example of the HDR menu
3.
Select the desired
Screen luminance unit
(nits or foot-Lambert).
4.
Enter the
Screen luminance
(which is measured in nits or foot-Lambert).
5.
Alter the
HDR boost
if necessary. You can modify this value to somewhere between 0.8 and 1.2.
Summary of Contents for F80-Q12
Page 1: ...ENABLING BRIGHT OUTCOMES User Manual F80 ...
Page 22: ...R5906852 09 F80 22 Safety ...
Page 34: ...R5906852 09 F80 34 Getting Started ...
Page 44: ...R5906852 09 F80 44 Remote Control Unit ...
Page 56: ...R5906852 09 F80 56 GUI Introduction ...
Page 62: ...R5906852 09 F80 62 GUI Source ...
Page 78: ...R5906852 09 F80 78 GUI Image ...
Page 146: ...R5906852 09 F80 146 GUI System Settings ...
Page 156: ...R5906852 09 F80 156 Advanced Settings ...
Page 160: ...R5906852 09 F80 160 GUI Status menu ...
Page 176: ...R5906852 09 F80 176 Specifications ...
Page 181: ...181 R5906852 09 F80 Image B 1 HDCP revision information Connector specifications ...
Page 182: ...R5906852 09 F80 182 Connector specifications ...
Page 186: ...R5906852 09 F80 186 Control interface specifications ...
Page 194: ...R5906852 09 F80 194 Regulatory information ...
Page 205: ...205 R5906852 09 F80 DMX chart F ...
Page 209: ......