MN761
Parameter Descriptions 7-19
7.4
I/O Group
Parameter #
Access
Parameter Name, Value Range, Description and Preset Value
RW
Jump Code
(Range: 0-63)
Sets the parameter number to jump to within I/O Group.
Allows quick access to a desired parameter.
Preset Value:
1
RW
Filter Time Constant for V0 Input
(Range: 0-9999)
Adjusts the analog voltage input signal by keypad potentiometer.
Preset Value:
10
RW
V0 Input Minimum Voltage
(Range: 0-10V)
Sets the minimum voltage of the V0 input.
Preset Value:
0
RW
Speed Corresponding to I2
(Range: 0-400Hz)
Sets the output frequency at minimum V0 input voltage set in I2.
Preset Value:
0.00
RW
V0 Input Maximum Voltage
(Range: 0-10V)
Sets the maximum voltage of the V0 input.
Preset Value:
10.00
RW
Speed Corresponding to I4
(Range: 0-400Hz)
Sets the output frequency at maximum V0 input voltage as set in I4.
Preset Value:
60.00
RW
Filter Time Constant for V1
(Range: 0-9999)
Sets the responsiveness of V1 Input (0-10V).
Preset Value:
10
RW
V1 Input Minimum Voltage
(Range: 0-10V)
Sets the minimum voltage of the V1 Input.
Preset Value:
0
RW
Speed Corresponding to I7
(Range: 0-400Hz)
Sets the output frequency at minimum V1 input voltage as set in I7.
Preset Value:
0.00
RW
V1 Input Maximum Voltage
(Range: 0-10V)
Sets the maximum voltage of the V1 input.
Preset Value:
10.00
RW
Speed Corresponding to I9
(Range: 0-400Hz)
Sets the maximum frequency at maximum V1 input voltage as set in I10.
Preset Value:
60.00
RW
Filter Time Constant for I Input
(Range: 0-9999)
Sets the internal filter constant of the input section for I input.
Preset Value:
10
Summary of Contents for VS1SM
Page 1: ...Installation Operating Manual VS1SM Single Phase AC Drive 10 07 MN761...
Page 10: ...2 2 General Information and Ratings MN761...
Page 28: ...6 8 Using the Keypad MN761...
Page 57: ...MN761 Customizing for Your Application 8 1 Chapter 8 Customizing for Your Application...
Page 58: ...8 2 Customizing for Your Application MN761...
Page 63: ...MN761 Parameter Tables B 1 Appendix B Parameter Tables Refer to Chapter 7...
Page 64: ...B 2 Parameter Tables MN761 B 1 1 Basic Parameters Continued...
Page 69: ...Baldor District Offices...