A-2 Technical Specifications
MN761
Keypad
Display
Display
2 line by 15 character LCD
Keys
9 key membrane with tactile response
Functions
Output status monitoring
Digital speed control
Parameter setting and display
Diagnostic and Fault log display
Motor run and jog
Local/Remote toggle
LED Indicators
Forward run command
Reverse run command
Stop command
Jog active
Remote Mount
200 feet (60.6m) maximum from control
Trip
Separate message for each trip, last 5 trips retained
in memory
Control Specifications
Control Method
V/Hz inverter, Sensorless vector
PWM Frequency
Adjustable 1.0-15kHz
Speed Setting
±
10 VDC, 0-10 VDC, 4-20 mA, external Pot,
digital (keypad),
Accel/Decel
0-6000 seconds
Velocity Loop Bandwidth
Adjustable to 180 Hz (Control only)
Current Loop Bandwidth
Adjustable to 1200 Hz (Control only)