7-22 Parameter Descriptions
MN761
7.4 I/O Group
Continued
Figure 7‐4
P5 (JOG)
Frequency
F20
Run Command (FX)
P1
P5
CM
FX : t1 = 0
JOG
t5=4
5 =
Speed Select 1
- (see Figure NO TAG)
6 =
Speed Select
2
- (see Figure NO TAG)
7 =
Speed Select 3
- (see Figure NO TAG)
Used to select Preset Speed 1 - 7 combinations, see P43-P45 and t10-t13, and Figure NO TAG.
8 =
Ramp Select1
- (see Figure NO TAG)
9 =
Ramp Select2
- (see Figure NO TAG)
10 =
Ramp Select3
- (see Figure NO TAG)
Used to define accel/decel ramp combinations for preset speeds, see (t14-t27).
11 =
DC brake during Stop:
DC voltage will be applied to the motor windings at a level set by DC Brake Start
Voltage (F12) for as long as the digital input is closed. See also F12 and F13 - Starting DC brake
parameters. See Figure 7‐5.
Figure 7‐5
Voltage
Run command
F12
P3
12 =
2nd motor select:
When input is present, the drive configures itself for a second set of motor settings
defined in 2nd motor operation parameters (H81 to H90).
13 = Reserved: Reserved
14 = Reserved: Reserved
15 =
Speed increase (UP)
: Increases the speed reference to the drive after a run command.
Frequency is saved to parameter F64 on a stop command if F63 = 1 `save up/down frequency'.
16 =
Speed decrease (DOWN)
: decreases the speed reference to the drive after a run command.
Frequency is saved to parameter F64 on a stop command if F63 = 1 `save up/down frequency'.
17 =
3-W ire operation
: Select to define a digital input for 3-Wire control. Inputs defined as forward (FX) and
reverse (RX) are momentary inputs and opening the input defined as 3-Wire operation will stop the drive.
For both 2-Wire and 3-Wire control, P38 - Drive Mode should be set to a 1 for normal operation.
See Figure 7‐6.
Summary of Contents for VS1SM
Page 1: ...Installation Operating Manual VS1SM Single Phase AC Drive 10 07 MN761...
Page 10: ...2 2 General Information and Ratings MN761...
Page 28: ...6 8 Using the Keypad MN761...
Page 57: ...MN761 Customizing for Your Application 8 1 Chapter 8 Customizing for Your Application...
Page 58: ...8 2 Customizing for Your Application MN761...
Page 63: ...MN761 Parameter Tables B 1 Appendix B Parameter Tables Refer to Chapter 7...
Page 64: ...B 2 Parameter Tables MN761 B 1 1 Basic Parameters Continued...
Page 69: ...Baldor District Offices...