MN761
Parameter Descriptions 7-21
7.4 I/O Group
Continued
Parameter #
Access
Parameter Name, Value Range, Description and Preset Value
RW
Programmable Digital Input Terminal P1-P5 Definition
(Range:
0- Forward Run.
1- Reverse Run.
2- Output Inhibit.
3- Fault Reset.
4- Jog.
5- Speed Select1.
6- Speed Select2.
7- Speed Select3.
8- Ramp Select1.
9- Ramp Select2.
10- Ramp Select3.
11- DC Brake During Stop.
12- Second Motor Selection.
13- N/A
14- N/A
15- Speed Increase.
16- Speed Decrease.
17- 3-Wire Operation.
18- External Trip: A Contact.
19- External Trip: B Contact.
20- N/A
21- PID or Volts/Hz Operation.
22- Option or Inverter.
23- Analog Hold.
24- Accel/Decel Disable.
Sets the operation mode of each Digital Input
Preset Value:
I20=0, I21=1, I22=2, I23=3, I24=4
RW
RW
RW
RW
0 =
Forward Run Command
: Defines a digital input as a forward run command in 2-Wire or 3-Wire control.
For both 2-Wire and 3-Wire control, P38 - Drive Mode should be set to a 1 for normal operation.
For 3-Wire control an additional terminal must be defined as 17 = 3-Wire operation.
1 =
Reverse Run Command
: Defines a digital input as a reverse run command in 2-Wire or 3-Wire control.
For both 2-Wire and 3-Wire control, P38 - Drive Mode should be set to a 1 for normal operation.
For 3-Wire control an additional terminal must be defined as 17 = 3-Wire operation.
2 =
Output Inhibit
: Defines a digital input as a drive Output Inhibit. As soon as this input is closed, the drive
output is instantly turned off and the motor will free wheel (coast to a rest). As soon as the input is opened,
the drive will resume previous operation (if in run, the drive will immediately accelerate to the set speed).
While the input is closed the drive display will show ESt [Instant Cut Off].
3 =
Fault Reset
: Active input resets the fault and resets the drive.
4 =
Jog
: When active, the drive ramps to the value set in Jog Frequency (F20).
Jog operation overrides all other operations except Dwell operation. If Jog Speed Command is entered
during a Preset Speed, Up-Down or 2-Wire control; operation is executed at Jog frequency, see Figure
7‐4. A valid start command is required separate from the dedicated jog input.
The jog function is only available for 2-Wire control.
Summary of Contents for VS1SM
Page 1: ...Installation Operating Manual VS1SM Single Phase AC Drive 10 07 MN761...
Page 10: ...2 2 General Information and Ratings MN761...
Page 28: ...6 8 Using the Keypad MN761...
Page 57: ...MN761 Customizing for Your Application 8 1 Chapter 8 Customizing for Your Application...
Page 58: ...8 2 Customizing for Your Application MN761...
Page 63: ...MN761 Parameter Tables B 1 Appendix B Parameter Tables Refer to Chapter 7...
Page 64: ...B 2 Parameter Tables MN761 B 1 1 Basic Parameters Continued...
Page 69: ...Baldor District Offices...